久久久久久亚洲欧洲 I 干干射 I 在线观看日本一区二区 I 色欲视频综合免费天天 I 奇米在线777 I 一区两区小视频 I 131mm少妇做爰视频 I 天天色人人爱 I 五月婷婷丁香在线 I 欧美国产黄色 I 国产亚洲精品久久久久久老妇小说 I 国产成人精品片 I 99热精品免费 I 国产99爱在线视频免费观看 I 欧美自拍另类欧美综合图片区 I 综合网国产 I 少妇厨房愉情理9伦片视频 I 午夜色在线观看 I 黄网页在线看 I 变态另类久久变态变态 I 日韩精品一区二区三区免费视频观看 I 国产精品不卡一区二区三区 I 三级影片在线免费观看 I 啪啪av影院 I 欧美综合站 I 狼人无码精华av午夜精品 I 亚洲综合色丁香婷婷六月图片 I 日本免费一区二区三区高清视频 I 国产精品免费观看视频 I 激情欧美一区二区三区免费看

Back

UHC Magnetic Level Gauge

UHC magnetic level gauge provides a safer, more reliable and more visible option than conventional glass level gauge. The float moves up and down with the change of level, and the float transmits the level signal through the coupling magnetic field, which divides into the local indication type and the remote transmission output type.
Chamber and float have a variety of materials and pressure-grade options and are suitable for complex process applications of current major operating devices.

Contact Us

Features

    1.The float adopts 304,316 L, TA2 and TC4 material. It has good temperature resistance and can reach to 450℃.

    2.The welding process meets the requirements of PED welding process. The chamber is made of 304,316 L. The maximum pressure can reach to 26 MPa.

    3.Local indicator type and remote output type with level alarm are optional.

    4.According to customer requirements, through a variety of production types, the products can be applied to a variety of working conditions.

Main Technical Parameters

1. UHC Magnetic level gauge side-mounted type local indicator

1.1 Side-mounted type magnetic level gauge (normal type)

Scope of application: The level gauge is the most common used side-mounted magnetic level gauge. It is suitable for level or interface measurement with nominal pressure which is not greater than 6.3MPa and the medium temperature is 0℃~+350℃.

Measurement range: 200mm~6000mm (Out of range is acceptable)

Nominal pressure: ≤6.3MPa

Nominal diameter: DN25 (or on request)

Ambient temperature: -40℃~+80℃

Medium temperature: 0℃≤T<350℃

Accuracy: ±5mm

Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3

Wetted material: 304, 316L or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

1.2 Side-mounted type magnetic level gauge (high temperature type)

Scope of application: This type magnetic level gauge is suitable for level or interface measurement in high temperature condition, which nominal pressure is not greater than 6.3 MPa and the medium temperature is 350℃~450℃.

Measurement range: 200mm~6000mm (Out of range is acceptable)

Nominal pressure: ≤6.3MPa

Nominal diameter: DN25 (or on request)

Ambient temperature: -40℃~+80℃

Medium temperature: 350℃≤T≤450℃

Accuracy: ±5mm

Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3

Wetted material: 304, 316L or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

Structure Features: Adopt a high temperature resistant aluminum nickel cobalt magnetic steel + ceramic magnetic column indicator

Side-mounted type magnetic level gauge (high pressure type)

Scope of application: It is suitable for the measurement of level or interface in high-pressure conditions which the maximum nominal pressure is 32MPa, and the medium temperature is 0℃~+450℃

Measurement range: 200mm~6000mm (Out of range is acceptable)

Nominal pressure: ≤32MPa

Nominal diameter: DN25 (or on request)

Ambient temperature: -40℃~+80℃

Medium temperature: 0℃≤T≤450℃

Accuracy: ±5mm

Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3

Wetted material: 304, 316L or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

Side-mounted type magnetic level gauge (Anticorrosive type)

Scope of application: 304 cylinder liner PTFE, is suitable for petroleum, chemical and other industries of strong corrosion medium level or boundary measurement.

Measurement range: 250mm~6500mm (Out of range is acceptable)

Nominal pressure: ≤2.5MPa

Nominal diameter: DN25 (or on request)

Ambient temperature: -40℃~+80℃

Medium temperature: -50℃≤T≤180℃ (It is related to medium)

Accuracy: ±5mm

Density: Level: ρ≥0.65g/cm3 Interface: ρ1-ρ2≥0.1g/cm3

Wetted material: chamber 304 internal lined with PTFE, float external lined with PTFE

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

Side-mounted type magnetic level gauge (Low temperature type)

Scope of application: It is suitable for measuring level or interface in low temperature and easy frost setting conditions.

Measurement range: 250mm~6500mm

Nominal pressure: ≤16.0MPa

Nominal diameter: DN25 (or on request)

Ambient temperature: -40℃~+80℃

Medium temperature: -40℃~0℃ (Indicator part: Vacuum sealed magnetic flap indicator)
-196℃~-40℃ (Indicator part: Vacuum sealed magnetic flap indicator with frost-proof extension)

Accuracy: ±5mm

Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.08g/cm3

Wetted material: 304, 316L or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

UHC Magnetic level gauge top-mounted type local indicator

Top-mounted type magnetic level gauge (normal type)

Scope of application: Top mounted type. It is suitable for level or interface measurement of various underground storage tanks and containers that are not suitable for opening on the side.

Measurement range: 200mm~4000mm (Out of range is acceptable)

Nominal pressure: ≤5MPa

Nominal diameter: DN150, DN100

Ambient temperature: -40℃~+80℃

Working temperature: -40℃≤T≤+450℃

Accuracy: ±5mm

Density: Level: ρ≥0.45g/cm3 Interface: ρ1-ρ2≥0.16g/cm3

Wetted material: 304, 316L or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or or on request

Top-mounted type magnetic level gauge (Anticorrosive type)

Scope of application: It is suitable for the measurement of level or interface of various underground storage tanks and containers that are not suitable for opening on the side and has strong corrosive medium.

Measurement range: 200mm~4000mm (Out of range is acceptable)

Nominal pressure: ≤5MPa

Nominal diameter: DN150, DN100

Ambient temperature: -40℃~+80℃

Working temperature: -40℃≤T≤+150℃

Accuracy: ±5mm

Density: Level: ρ≥0.7g/cm3 Interface: ρ1-ρ2≥0.16g/cm3

Wetted material: 304+PTFE or on request

Flange standard: HG/T20592-2009,HG/T20615-2009 or on request

Applications

Refining: diesel storage tank, catalytic reformers, acid-containing sedimentation tank, hydrocracking, hydrogenation desulfurization, coking unit, solvent extraction, alkylation tank, isomerization, crude oil storage, crude oil desalination, reboiler, distillation tower

Chemical: Demineralized water tank, fermentation tank, chemical reactor, vapor drum in chemical industry, chemical injection, buffer tank, chlor-alkali process, condenser, vapor-liquid separation, liquid ammonia storage, liquid-liquid extraction

Natural Gas: chemical injection, light hydrocarbon recovery, acid gas recovery

Sewage Treatment: plant water

Crude Oil Treatment: crude oil dehydration, drilling fluid storage tank

Electricity: desalination tank, deaerator, power plant vapor drum, feed water heater, boiler sewage tank, lubricating oil tank, flash tank, washing tank, waste heat boiler, pre-flash tank

Solution